Technical characteristics
• When 4116 is used in combination with the PR 4500 display series,
all operational parameters can be modified to suit any application.
• As the 4116 is designed with electronic hardware switches,
it is not necessary to open the device for setting of DIP-switches.
• A green / red front LED indicates normal operation and malfunction.
A yellow LED is ON for each active output relay.
• Continuous check of vital stored data for safety reasons.
• 4-port 2.3 kVAC galvanic isolation.
Mounting / installation / programming
• Very low power consumption means units can be mounted side by side
without an air gap – even at 60°C ambient temperature.
• Configuration, monitoring, 2-point process calibration and more
are accomplished using PR's 4500 series of detachable displays.
• All programming can be password-protected.
• Linearized, electronic temperature measurement with RTD or TC sensor.
• Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
• Power supply and signal isolator for 2-wire transmitters.
• Process control with 2 pairs of potential-free relay contacts and analog output.
• Galvanic separation of analog signals and measurement of floating signals.
• The 4116 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
• Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
• Input for RTD, TC, Ohm, potentiometer, mA and V
• 2-wire supply > 16 V
• FM-approved for installation in Div. 2
• Output for current, voltage and 2 relays
• Universal AC or DC supply