<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Magnetic Flow Meters | InstruMetrics</title>
	<atom:link href="https://instrumetrics.com/product-category/process-instrumentation/flow/magnetic-flow-meters/feed/" rel="self" type="application/rss+xml" />
	<link>https://instrumetrics.com/product-category/process-instrumentation/flow/magnetic-flow-meters/</link>
	<description>InstruMetrics Engineering</description>
	<lastBuildDate>Mon, 27 Jun 2022 09:15:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://instrumetrics.com/wp-content/uploads/2022/04/cropped-favicon-32x32.png</url>
	<title>Magnetic Flow Meters | InstruMetrics</title>
	<link>https://instrumetrics.com/product-category/process-instrumentation/flow/magnetic-flow-meters/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TRANSMAG 2 AC powered Magnetic flowmeter</title>
		<link>https://instrumetrics.com/product/transmag-2-ac-powered-magnetic-flowmeter/</link>
					<comments>https://instrumetrics.com/product/transmag-2-ac-powered-magnetic-flowmeter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=641</guid>

					<description><![CDATA[<p><strong>High-powered flowmeter consists of the SITRANS F M TRANSMAG 2 transmitter and the sensor SITRANS F M 911/E</strong><br />
Best choice for special applications such as pulsating flow, media with low conductivity and high percentage of solids. sensor is a pulsed <a href="https://en.wikipedia.org/wiki/Alternating_current" target="_blank" rel="noopener">alternating field</a> <a href="https://en.wikipedia.org/wiki/Magnetic_flow_meter" target="_blank" rel="noopener">magnetic flowmeter</a> where the magnetic field strength is much higher than <a href="https://en.wikipedia.org/wiki/Electric_current" target="_blank" rel="noopener">conventional DC </a>pulsed magnetic flowmeters.</p>
<p><strong>The main applications</strong> of the SITRANS FM <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a><br />
TRANSMAG 2 can be found in the following sectors:<br />
• Pulp and Paper industry<br />
• <a href="https://translate.google.co.il/?hl=iw&#38;tab=rT&#38;sl=en&#38;tl=iw&#38;text=Mining%20industry&#38;op=translate" target="_blank" rel="noopener">Mining industry</a><br />
The patented pulse alternating field technology is ideal for difficult applications like:<br />
• High concentrated paper stock &#62; 3 %<br />
• Heavy mining slurries up to 70 % solid concentration<br />
• Mining slurries with magnetic particles.<br />
• Low <a href="https://en.wikipedia.org/wiki/Conductivity_(electrolytic)" target="_blank" rel="noopener">conductive</a> medias ≥1 μS/cm (0.1 μS/cm depending on medium)</p>
<p><strong>Design</strong><br />
• Available for remote mounting<br />
• <a href="https://us.profinet.com/what-is-the-difference-between-profibus-dp-and-pa/" target="_blank" rel="noopener">PROFIBUS PA</a> (profile 2.0) / HART communication<br />
• Analog output and digital outputs for pulses, device status,<br />
limits, flow direction, <a href="https://en.wikipedia.org/wiki/Frequency_divider" target="_blank" rel="noopener">frequency output 110</a></p>
<p>The post <a href="https://instrumetrics.com/product/transmag-2-ac-powered-magnetic-flowmeter/">TRANSMAG 2 AC powered Magnetic flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>High-powered flowmeter consists of the SITRANS F M TRANSMAG 2 transmitter and the sensor SITRANS F M 911/E</strong><br />
Best choice for special applications such as pulsating flow, media with low conductivity and high percentage of solids. sensor is a pulsed <a href="https://en.wikipedia.org/wiki/Alternating_current" target="_blank" rel="noopener">alternating field</a> <a href="https://en.wikipedia.org/wiki/Magnetic_flow_meter" target="_blank" rel="noopener">magnetic flowmeter</a> where the magnetic field strength is much higher than <a href="https://en.wikipedia.org/wiki/Electric_current" target="_blank" rel="noopener">conventional DC </a>pulsed magnetic flowmeters.</p>
<p><strong>The main applications</strong> of the SITRANS FM <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a><br />
TRANSMAG 2 can be found in the following sectors:<br />
• Pulp and Paper industry<br />
• <a href="https://translate.google.co.il/?hl=iw&amp;tab=rT&amp;sl=en&amp;tl=iw&amp;text=Mining%20industry&amp;op=translate" target="_blank" rel="noopener">Mining industry</a><br />
The patented pulse alternating field technology is ideal for difficult applications like:<br />
• High concentrated paper stock &gt; 3 %<br />
• Heavy mining slurries up to 70 % solid concentration<br />
• Mining slurries with magnetic particles.<br />
• Low <a href="https://en.wikipedia.org/wiki/Conductivity_(electrolytic)" target="_blank" rel="noopener">conductive</a> medias ≥1 μS/cm (0.1 μS/cm depending on medium)</p>
<p><strong>Design</strong><br />
• Available for remote mounting<br />
• <a href="https://us.profinet.com/what-is-the-difference-between-profibus-dp-and-pa/" target="_blank" rel="noopener">PROFIBUS PA</a> (profile 2.0) / HART communication<br />
• Analog output and digital outputs for pulses, device status,<br />
limits, flow direction, <a href="https://en.wikipedia.org/wiki/Frequency_divider" target="_blank" rel="noopener">frequency output 110</a></p>
<p>The post <a href="https://instrumetrics.com/product/transmag-2-ac-powered-magnetic-flowmeter/">TRANSMAG 2 AC powered Magnetic flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/transmag-2-ac-powered-magnetic-flowmeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SITRANS F C MASS 6000 Transmitter</title>
		<link>https://instrumetrics.com/product/sitrans-f-c-mass-6000-transmitter/</link>
					<comments>https://instrumetrics.com/product/sitrans-f-c-mass-6000-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:52:18 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=584</guid>

					<description><![CDATA[<p>The SITRANS F C MASS 6000 is based on the latest developments within <a href="https://en.wikipedia.org/wiki/Digital_signal_processing" target="_blank" rel="noopener">digital signal processing technology</a> – engineered for high performance, fast flow step response, fast <a href="https://translate.google.co.il/?hl=iw&#38;tab=wT&#38;sl=en&#38;tl=iw&#38;text=batching%20applications&#38;op=translate" target="_blank" rel="noopener">batching applications</a>, high immunity against <a href="https://en.wikipedia.org/wiki/Noise_(signal_processing)" target="_blank" rel="noopener">process noise</a>, easy to install, commission and maintain. The <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> delivers true multi parameter measurements i.e. mass flow, volume flow, density, temperature and fraction.</p>
<p><a href="https://en.wikipedia.org/wiki/Resistance_thermometer" target="_blank" rel="noopener">4-wire Pt1000</a> temperature measurement ensures optimum<br />
accuracy on mass flow, density and fraction flow.<br />
• Fraction flow computation based on a <a href="https://en.wikipedia.org/wiki/Sorting_algorithm" target="_blank" rel="noopener">3rd-order algorithm</a><br />
matching all applications.<br />
• <a href="https://en.wikipedia.org/wiki/Simple_Network_Management_Protocol" target="_blank" rel="noopener">USM II platform</a> enables fitting of add-on bus modules without<br />
loss of functionality.<br />
- All modules can be fitted through true "plug &#38; play"<br />
- Module and transmitter are automatically configured through<br />
the <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&#38;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a>.<br />
• Installation of the transmitter to the sensor is simple "plug &#38;<br />
play" via the sensor <a href="https://translate.google.co.il/?hl=iw&#38;tab=rT&#38;sl=en&#38;tl=iw&#38;text=pedestal&#38;op=translate" target="_blank" rel="noopener">pedestal</a></p>
<p><strong>Application</strong><br />
SITRANS F C mass flowmeters are suitable for all applications within the entire process industry, where there is a demand for accurate flow measurement. The meter is capable of measuring both liquid and gas flow. The main applications for the MASS 6000 IP67 transmitter can<br />
be found in:<br />
• Food and beverage industries<br />
• Pharmaceutical industries<br />
• Automotive industry<br />
• Oil and gas industry<br />
• Power generation and utility industry<br />
• Water and waste water industry</p>
<p>The post <a href="https://instrumetrics.com/product/sitrans-f-c-mass-6000-transmitter/">SITRANS F C MASS 6000 Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SITRANS F C MASS 6000 is based on the latest developments within <a href="https://en.wikipedia.org/wiki/Digital_signal_processing" target="_blank" rel="noopener">digital signal processing technology</a> – engineered for high performance, fast flow step response, fast <a href="https://translate.google.co.il/?hl=iw&amp;tab=wT&amp;sl=en&amp;tl=iw&amp;text=batching%20applications&amp;op=translate" target="_blank" rel="noopener">batching applications</a>, high immunity against <a href="https://en.wikipedia.org/wiki/Noise_(signal_processing)" target="_blank" rel="noopener">process noise</a>, easy to install, commission and maintain. The <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> delivers true multi parameter measurements i.e. mass flow, volume flow, density, temperature and fraction.</p>
<p><a href="https://en.wikipedia.org/wiki/Resistance_thermometer" target="_blank" rel="noopener">4-wire Pt1000</a> temperature measurement ensures optimum<br />
accuracy on mass flow, density and fraction flow.<br />
• Fraction flow computation based on a <a href="https://en.wikipedia.org/wiki/Sorting_algorithm" target="_blank" rel="noopener">3rd-order algorithm</a><br />
matching all applications.<br />
• <a href="https://en.wikipedia.org/wiki/Simple_Network_Management_Protocol" target="_blank" rel="noopener">USM II platform</a> enables fitting of add-on bus modules without<br />
loss of functionality.<br />
&#8211; All modules can be fitted through true &#8220;plug &amp; play&#8221;<br />
&#8211; Module and transmitter are automatically configured through<br />
the <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&amp;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a>.<br />
• Installation of the transmitter to the sensor is simple &#8220;plug &amp;<br />
play&#8221; via the sensor <a href="https://translate.google.co.il/?hl=iw&amp;tab=rT&amp;sl=en&amp;tl=iw&amp;text=pedestal&amp;op=translate" target="_blank" rel="noopener">pedestal</a></p>
<p><strong>Application</strong><br />
SITRANS F C mass flowmeters are suitable for all applications within the entire process industry, where there is a demand for accurate flow measurement. The meter is capable of measuring both liquid and gas flow. The main applications for the MASS 6000 IP67 transmitter can<br />
be found in:<br />
• Food and beverage industries<br />
• Pharmaceutical industries<br />
• Automotive industry<br />
• Oil and gas industry<br />
• Power generation and utility industry<br />
• Water and waste water industry</p>
<p>The post <a href="https://instrumetrics.com/product/sitrans-f-c-mass-6000-transmitter/">SITRANS F C MASS 6000 Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/sitrans-f-c-mass-6000-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SITRANS F M MAG 6000</title>
		<link>https://instrumetrics.com/product/sitrans-f-m-mag-6000/</link>
					<comments>https://instrumetrics.com/product/sitrans-f-m-mag-6000/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:52:18 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=586</guid>

					<description><![CDATA[<p>The SITRANS F M MAG 6000 is a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor</a>-based transmitter engineered for high performance, easy installation, commissio­ning and maintenance. The <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> is robust and suitable for all-round applications, has a measuring accuracy of ± 0.2% of the flow rate and can be fitted with optional plug-in communication modules.</p>
<p><strong>Application</strong><br />
The SITRANS FM flowmeters are suitable for measuring the flow<br />
of almost all electrically <a href="https://en.wikipedia.org/wiki/Level_sensor" target="_blank" rel="noopener">conductive liquids</a>, pastes and slurries.<br />
<strong>The main applications can be found in:</strong><br />
• Water and waste water<br />
• Chemical and pharmaceutical industries<br />
• Food and beverage industries<br />
• Power generation and utility</p>
<p><strong>The MAG 5000/6000</strong> are transmitters with a build-in <a href="https://en.wikipedia.org/wiki/Fourteen-segment_display" target="_blank" rel="noopener">alphanumeric display</a> in several languages. The transmitters evaluate<br />
the signals from the associated <a href="https://www.hindawi.com/journals/js/si/460287/" target="_blank" rel="noopener">electromagnetic sensors</a> and also fulfil the task of a power supply unit which provides the<br />
magnet coils with a constant current. Further information on connection, mode of operation and installation can be found in the data sheets for the sensors. Displays and controls Operation of the transmitter can be carried out using:<br />
• Control and display unit<br />
• <a href="https://en.wikipedia.org/wiki/WirelessHART" target="_blank" rel="noopener">HART communicator</a><br />
• PC/laptop and SIMATIC PDM software via HART communication<br />
• PC/laptop and SIMATIC PDM software using <a href="https://en.wikipedia.org/wiki/Profibus" target="_blank" rel="noopener">PROFIBUS</a> or <a href="https://en.wikipedia.org/wiki/Modbus" target="_blank" rel="noopener">Modbus communication</a></p>
<p>The post <a href="https://instrumetrics.com/product/sitrans-f-m-mag-6000/">SITRANS F M MAG 6000</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SITRANS F M MAG 6000 is a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor</a>-based transmitter engineered for high performance, easy installation, commissio­ning and maintenance. The <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> is robust and suitable for all-round applications, has a measuring accuracy of ± 0.2% of the flow rate and can be fitted with optional plug-in communication modules.</p>
<p><strong>Application</strong><br />
The SITRANS FM flowmeters are suitable for measuring the flow<br />
of almost all electrically <a href="https://en.wikipedia.org/wiki/Level_sensor" target="_blank" rel="noopener">conductive liquids</a>, pastes and slurries.<br />
<strong>The main applications can be found in:</strong><br />
• Water and waste water<br />
• Chemical and pharmaceutical industries<br />
• Food and beverage industries<br />
• Power generation and utility</p>
<p><strong>The MAG 5000/6000</strong> are transmitters with a build-in <a href="https://en.wikipedia.org/wiki/Fourteen-segment_display" target="_blank" rel="noopener">alphanumeric display</a> in several languages. The transmitters evaluate<br />
the signals from the associated <a href="https://www.hindawi.com/journals/js/si/460287/" target="_blank" rel="noopener">electromagnetic sensors</a> and also fulfil the task of a power supply unit which provides the<br />
magnet coils with a constant current. Further information on connection, mode of operation and installation can be found in the data sheets for the sensors. Displays and controls Operation of the transmitter can be carried out using:<br />
• Control and display unit<br />
• <a href="https://en.wikipedia.org/wiki/WirelessHART" target="_blank" rel="noopener">HART communicator</a><br />
• PC/laptop and SIMATIC PDM software via HART communication<br />
• PC/laptop and SIMATIC PDM software using <a href="https://en.wikipedia.org/wiki/Profibus" target="_blank" rel="noopener">PROFIBUS</a> or <a href="https://en.wikipedia.org/wiki/Modbus" target="_blank" rel="noopener">Modbus communication</a></p>
<p>The post <a href="https://instrumetrics.com/product/sitrans-f-m-mag-6000/">SITRANS F M MAG 6000</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/sitrans-f-m-mag-6000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MAG 1100 Wafer Design SST Magnetic flowmeter</title>
		<link>https://instrumetrics.com/product/mag-1100-wafer-design-sst-magnetic-flowmeter/</link>
					<comments>https://instrumetrics.com/product/mag-1100-wafer-design-sst-magnetic-flowmeter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=502</guid>

					<description><![CDATA[<p>SITRANS FM MAG 1100, designed for general industry environments, has a <a href="https://en.wikipedia.org/wiki/Wafer_(electronics)" target="_blank" rel="noopener">wafer</a> design <a href="https://en.wikipedia.org/wiki/Sensor" target="_blank" rel="noopener">sensor</a> in <a href="https://en.wikipedia.org/wiki/Corrosion" target="_blank" rel="noopener">corrosion</a>-resistant <a href="https://en.wikipedia.org/wiki/Stainless_steel" target="_blank" rel="noopener">stainless steel</a> housing. Highly <a href="https://en.wikipedia.org/wiki/Copper%E2%80%93tungsten" target="_blank" rel="noopener">resistant liners and electrodes</a> are suitable for harsh process conditions.</p>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_44913" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a645c4ed-2b1a-424c-914b-dc2b3cf9f334">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Accuracy 0.2 % ±1 mm/s 0.4 % ±1 mm/s (<a href="https://en.wikipedia.org/wiki/Paraformaldehyde" target="_blank" rel="noopener">PFA</a>)</li>
<li>Compact wafer design meets <a href="https://en.wikipedia.org/wiki/List_of_EN_standards" target="_blank" rel="noopener">EN 1092</a>, <a href="https://en.wikipedia.org/wiki/List_of_DIN_standards" target="_blank" rel="noopener">DIN</a> and ANSI flange standards</li>
<li>Easy Plug &#38; Play field changeability of <a href="https://instrumetrics.com/?post_type=product&#38;lang=ICL_LANGUAGE_CODE&#38;s=Transmitter" target="_blank" rel="noopener">transmitter</a></li>
<li>Compact or remote mounting possible</li>
<li>Highly <a href="https://en.wikipedia.org/wiki/Copper%E2%80%93tungsten" target="_blank" rel="noopener">resistant liner and electrodes</a> that are suitable for most extreme process media</li>
<li>Designed to allow patented MAG in-situ verification using the <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&#38;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a> fingerprint</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top color-snow white-bg" data-ste-section="Detail_51703" data-colour-theme="color-snow" data-background-theme="white-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-1100-wafer-design-sst-magnetic-flowmeter/">MAG 1100 Wafer Design SST Magnetic flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SITRANS FM MAG 1100, designed for general industry environments, has a <a href="https://en.wikipedia.org/wiki/Wafer_(electronics)" target="_blank" rel="noopener">wafer</a> design <a href="https://en.wikipedia.org/wiki/Sensor" target="_blank" rel="noopener">sensor</a> in <a href="https://en.wikipedia.org/wiki/Corrosion" target="_blank" rel="noopener">corrosion</a>-resistant <a href="https://en.wikipedia.org/wiki/Stainless_steel" target="_blank" rel="noopener">stainless steel</a> housing. Highly <a href="https://en.wikipedia.org/wiki/Copper%E2%80%93tungsten" target="_blank" rel="noopener">resistant liners and electrodes</a> are suitable for harsh process conditions.</p>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_44913" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a645c4ed-2b1a-424c-914b-dc2b3cf9f334">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Accuracy 0.2 % ±1 mm/s 0.4 % ±1 mm/s (<a href="https://en.wikipedia.org/wiki/Paraformaldehyde" target="_blank" rel="noopener">PFA</a>)</li>
<li>Compact wafer design meets <a href="https://en.wikipedia.org/wiki/List_of_EN_standards" target="_blank" rel="noopener">EN 1092</a>, <a href="https://en.wikipedia.org/wiki/List_of_DIN_standards" target="_blank" rel="noopener">DIN</a> and ANSI flange standards</li>
<li>Easy Plug &amp; Play field changeability of <a href="https://instrumetrics.com/?post_type=product&amp;lang=ICL_LANGUAGE_CODE&amp;s=Transmitter" target="_blank" rel="noopener">transmitter</a></li>
<li>Compact or remote mounting possible</li>
<li>Highly <a href="https://en.wikipedia.org/wiki/Copper%E2%80%93tungsten" target="_blank" rel="noopener">resistant liner and electrodes</a> that are suitable for most extreme process media</li>
<li>Designed to allow patented MAG in-situ verification using the <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&amp;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a> fingerprint</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top color-snow white-bg" data-ste-section="Detail_51703" data-colour-theme="color-snow" data-background-theme="white-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-1100-wafer-design-sst-magnetic-flowmeter/">MAG 1100 Wafer Design SST Magnetic flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/mag-1100-wafer-design-sst-magnetic-flowmeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SITRANS FM MAG 3100</title>
		<link>https://instrumetrics.com/product/sitrans-fm-mag-3100/</link>
					<comments>https://instrumetrics.com/product/sitrans-fm-mag-3100/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=503</guid>

					<description><![CDATA[<p>SITRANS FM MAG 3100 is an <a href="https://en.wikipedia.org/wiki/Inductive_sensor" target="_blank" rel="noopener">electromagnetic flow sensor</a> with a large variety of liners, <a href="https://en.wikipedia.org/wiki/Electrode" target="_blank" rel="noopener">electrode material</a> and with <a href="https://en.wikipedia.org/wiki/Ground_(electricity)" target="_blank" rel="noopener">grounding electrode</a>s as standard, all this ensures a perfect fit for almost every <a href="https://instrumetrics.com/product-category/process-instrumentation/flow/" target="_blank" rel="noopener">flow</a> application.</p>
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a15b3781-e223-4371-9d8a-ce5e1f4e8e90">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Fully <a href="https://translate.google.co.il/?hl=iw&#38;tab=rT&#38;sl=en&#38;tl=iw&#38;text=welded&#38;op=translate" target="_blank" rel="noopener">welded</a> construction that is extremely rugged and can withstand special process conditions using extreme <a href="https://en.wikipedia.org/wiki/Ion-selective_electrode" target="_blank" rel="noopener">measurement electrodes</a></li>
<li>Universal applications - lining and electrodes available for every application</li>
<li>High temperature version available up to 356 °F</li>
<li>Approved for use in potentially <a href="https://en.wikipedia.org/wiki/ATEX_directive" target="_blank" rel="noopener">explosive atmospheres</a></li>
<li>SITRANS FM portfolio - our integrated platform enables flexible use of the MAG 5000 / 6000 transmitter for all products (MAG 5100 / 3100/1100):<br />
• Unique <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&#38;lc=en-WW" target="_blank" rel="noopener">SensorProm</a> technology - stores critical, <a href="https://en.wikipedia.org/wiki/Wireless_sensor_network" target="_blank" rel="noopener">sensor-specific data</a> and passes it to the <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a>. This allows a simple, flexible commissioning of the sensor.<br />
• Plug &#38; Play - allows easy on-site replacement and commissioning of the transmitter in just minutes<br />
• "Hot swapable" - exchangeable during operation<br />
• Mounting flexibility - compact or separate installation possible<br />
• <a href="https://en.wikipedia.org/wiki/Verification_and_validation" target="_blank" rel="noopener">Validated calibration</a> ensures accurate flow measurement. Each Siemens <a href="https://search.dc.siemens.com/?q=flowmeters&#38;lr=lang_en&#38;site=siemens_c_ww&#38;filetypes=%2a&#38;lang=en&#38;h=new.siemens.com%2Fglobal%2Fen.html" target="_blank" rel="noopener">flowmeter</a> is calibrated in facilities that are individually accredited to <a href="https://en.wikipedia.org/wiki/ISO/IEC_17025" target="_blank" rel="noopener">ISO / IEC 17025</a>.<br />
• Service and diagnostics - designed for MAG on-site verification with traceable certification. Regular <a href="https://instrumetrics.com/product-category/calibration-test-equipment/flow-calibrators/" target="_blank" rel="noopener">calibration</a> of the SITRANS FM Verificator ensures accuracy in the field.</li>
</ul>
</div>
</div>
</div>
</div>
<p>The post <a href="https://instrumetrics.com/product/sitrans-fm-mag-3100/">SITRANS FM MAG 3100</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SITRANS FM MAG 3100 is an <a href="https://en.wikipedia.org/wiki/Inductive_sensor" target="_blank" rel="noopener">electromagnetic flow sensor</a> with a large variety of liners, <a href="https://en.wikipedia.org/wiki/Electrode" target="_blank" rel="noopener">electrode material</a> and with <a href="https://en.wikipedia.org/wiki/Ground_(electricity)" target="_blank" rel="noopener">grounding electrode</a>s as standard, all this ensures a perfect fit for almost every <a href="https://instrumetrics.com/product-category/process-instrumentation/flow/" target="_blank" rel="noopener">flow</a> application.</p>
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a15b3781-e223-4371-9d8a-ce5e1f4e8e90">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Fully <a href="https://translate.google.co.il/?hl=iw&amp;tab=rT&amp;sl=en&amp;tl=iw&amp;text=welded&amp;op=translate" target="_blank" rel="noopener">welded</a> construction that is extremely rugged and can withstand special process conditions using extreme <a href="https://en.wikipedia.org/wiki/Ion-selective_electrode" target="_blank" rel="noopener">measurement electrodes</a></li>
<li>Universal applications &#8211; lining and electrodes available for every application</li>
<li>High temperature version available up to 356 °F</li>
<li>Approved for use in potentially <a href="https://en.wikipedia.org/wiki/ATEX_directive" target="_blank" rel="noopener">explosive atmospheres</a></li>
<li>SITRANS FM portfolio &#8211; our integrated platform enables flexible use of the MAG 5000 / 6000 transmitter for all products (MAG 5100 / 3100/1100):<br />
• Unique <a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&amp;lc=en-WW" target="_blank" rel="noopener">SensorProm</a> technology &#8211; stores critical, <a href="https://en.wikipedia.org/wiki/Wireless_sensor_network" target="_blank" rel="noopener">sensor-specific data</a> and passes it to the <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a>. This allows a simple, flexible commissioning of the sensor.<br />
• Plug &amp; Play &#8211; allows easy on-site replacement and commissioning of the transmitter in just minutes<br />
• &#8220;Hot swapable&#8221; &#8211; exchangeable during operation<br />
• Mounting flexibility &#8211; compact or separate installation possible<br />
• <a href="https://en.wikipedia.org/wiki/Verification_and_validation" target="_blank" rel="noopener">Validated calibration</a> ensures accurate flow measurement. Each Siemens <a href="https://search.dc.siemens.com/?q=flowmeters&amp;lr=lang_en&amp;site=siemens_c_ww&amp;filetypes=%2a&amp;lang=en&amp;h=new.siemens.com%2Fglobal%2Fen.html" target="_blank" rel="noopener">flowmeter</a> is calibrated in facilities that are individually accredited to <a href="https://en.wikipedia.org/wiki/ISO/IEC_17025" target="_blank" rel="noopener">ISO / IEC 17025</a>.<br />
• Service and diagnostics &#8211; designed for MAG on-site verification with traceable certification. Regular <a href="https://instrumetrics.com/product-category/calibration-test-equipment/flow-calibrators/" target="_blank" rel="noopener">calibration</a> of the SITRANS FM Verificator ensures accuracy in the field.</li>
</ul>
</div>
</div>
</div>
</div>
<p>The post <a href="https://instrumetrics.com/product/sitrans-fm-mag-3100/">SITRANS FM MAG 3100</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/sitrans-fm-mag-3100/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SITRANS FM MAG 3100 P</title>
		<link>https://instrumetrics.com/product/sitrans-fm-mag-3100-p/</link>
					<comments>https://instrumetrics.com/product/sitrans-fm-mag-3100-p/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=504</guid>

					<description><![CDATA[<p>The SITRANS F M  MAG 3100 P sensor  is designed to meet the most common specifications within the chemical and process industries. It has PTFE or PFA liners and Hastelloy electrodes being the ideal combination. The fully welded construction provides a ruggedness that fits almost every flow application.</p>
<p>The post <a href="https://instrumetrics.com/product/sitrans-fm-mag-3100-p/">SITRANS FM MAG 3100 P</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="introduction__textBlock textBlock textBlock--withMedia ">
<p class="introduction__text textBlock__description">The SITRANS FM MAG 3100 P sensor is designed to meet the most common specifications within the chemical and process industries.</p>
</div>
<p>The post <a href="https://instrumetrics.com/product/sitrans-fm-mag-3100-p/">SITRANS FM MAG 3100 P</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/sitrans-fm-mag-3100-p/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MAG 5000 Transmitter</title>
		<link>https://instrumetrics.com/product/mag-5000-transmitter/</link>
					<comments>https://instrumetrics.com/product/mag-5000-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=505</guid>

					<description><![CDATA[<p>The SITRANS F M MAG 5000 is a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor-based</a> <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> engineered for high performance, easy installation, commissioning and maintenance. The transmitter is truly robust, cost-effective and suitable for all-round applications and has a measuring <a href="https://en.wikipedia.org/wiki/Accuracy_and_precision" target="_blank" rel="noopener">accuracy of ± 0.4%</a> of the flow rate (incl. sensor).</p>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_21226" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a3330e2e-519a-4869-bf44-dc692b99ffbf">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Cost effective transmitter with good performance</li>
<li><a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&#38;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a> technology facilitates easy transmitter without loss of data and accuracy</li>
<li>Multiple functional output for process control</li>
<li>Multi-lingual display and <a href="https://en.wikipedia.org/wiki/Numeric_keypad" target="_blank" rel="noopener">keypad interface</a></li>
<li>Comprehensive diagnostic and service menu enhancing <a href="https://en.wikipedia.org/wiki/Troubleshooting" target="_blank" rel="noopener">trouble shooting</a> and <a href="http://meter verificatio" target="_blank" rel="noopener">meter verificatio</a>n</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top color-snow white-bg" data-ste-section="Detail_30958" data-colour-theme="color-snow" data-background-theme="white-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-5000-transmitter/">MAG 5000 Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SITRANS F M MAG 5000 is a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor-based</a> <a href="https://en.wikipedia.org/wiki/Transmitter" target="_blank" rel="noopener">transmitter</a> engineered for high performance, easy installation, commissioning and maintenance. The transmitter is truly robust, cost-effective and suitable for all-round applications and has a measuring <a href="https://en.wikipedia.org/wiki/Accuracy_and_precision" target="_blank" rel="noopener">accuracy of ± 0.4%</a> of the flow rate (incl. sensor).</p>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_21226" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="a3330e2e-519a-4869-bf44-dc692b99ffbf">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Cost effective transmitter with good performance</li>
<li><a href="https://support.industry.siemens.com/cs/document/66489654/what-is-the-main-difference-between-sensorprom-and-sensorflash-?dti=0&amp;lc=en-WW" target="_blank" rel="noopener">SENSORPROM</a> technology facilitates easy transmitter without loss of data and accuracy</li>
<li>Multiple functional output for process control</li>
<li>Multi-lingual display and <a href="https://en.wikipedia.org/wiki/Numeric_keypad" target="_blank" rel="noopener">keypad interface</a></li>
<li>Comprehensive diagnostic and service menu enhancing <a href="https://en.wikipedia.org/wiki/Troubleshooting" target="_blank" rel="noopener">trouble shooting</a> and <a href="http://meter verificatio" target="_blank" rel="noopener">meter verificatio</a>n</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top color-snow white-bg" data-ste-section="Detail_30958" data-colour-theme="color-snow" data-background-theme="white-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-5000-transmitter/">MAG 5000 Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/mag-5000-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MAG 5100 W</title>
		<link>https://instrumetrics.com/product/mag-5100-w/</link>
					<comments>https://instrumetrics.com/product/mag-5100-w/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=506</guid>

					<description><![CDATA[<p>The SITRANS F M  MAG 5100 W  with its patented liners of hard rubber <a href="https://en.wikipedia.org/wiki/Nitrile_rubber" target="_blank" rel="noopener">NBR</a> or <a href="https://en.wikipedia.org/wiki/Ebonite" target="_blank" rel="noopener">ebonite</a> and <a href="https://en.wikipedia.org/wiki/EPDM_rubber" target="_blank" rel="noopener">EPDM</a> is a <a href="https://en.wikipedia.org/wiki/Sensor" target="_blank" rel="noopener">sensor</a> for all water applications such as ground water, drinking water, cooling water, waste water, sewage or sludge applications. Accuracy 0.2 % ±2.5 mm/s.</p>
<p>The post <a href="https://instrumetrics.com/product/mag-5100-w/">MAG 5100 W</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SITRANS F M  MAG 5100 W  with its patented liners of hard rubber <a href="https://en.wikipedia.org/wiki/Nitrile_rubber" target="_blank" rel="noopener">NBR</a> or <a href="https://en.wikipedia.org/wiki/Ebonite" target="_blank" rel="noopener">ebonite</a> and <a href="https://en.wikipedia.org/wiki/EPDM_rubber" target="_blank" rel="noopener">EPDM</a> is a <a href="https://en.wikipedia.org/wiki/Sensor" target="_blank" rel="noopener">sensor</a> for all water applications such as ground water, drinking water, cooling water, waste water, sewage or sludge applications. Accuracy 0.2 % ±2.5 mm/s.</p>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_82276" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top color-snow white-bg" data-ste-section="Detail_55340" data-colour-theme="color-snow" data-background-theme="white-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base"></div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-5100-w/">MAG 5100 W</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/mag-5100-w/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MAG 6000I / 6000I(Ex) Transmitter</title>
		<link>https://instrumetrics.com/product/mag-6000i-6000iex-transmitter/</link>
					<comments>https://instrumetrics.com/product/mag-6000i-6000iex-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=507</guid>

					<description><![CDATA[<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_71429" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_71429" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title"></div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="22c6231a-f88a-417a-9bfc-671433fae3a3">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<p>The SITRANS F M MAG 6000 I and the SITRANS F M MAG 6000 I Ex de <a href="https://en.wikipedia.org/wiki/Transmitter">transmitters</a> have an measuring accuracy of + 0.2% of the flow rate and are designed to meet the demands of the process industry. Both versions are based on a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor</a> with a built-in <a href="https://en.wikipedia.org/wiki/Fourteen-segment_display" target="_blank" rel="noopener">alphanumeric display.</a></p>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="section-container row aem-GridColumn aem-GridColumn--default--12"></div>
</div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-6000i-6000iex-transmitter/">MAG 6000I / 6000I(Ex) Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="section-container row aem-GridColumn aem-GridColumn--default--12">
<section class="contentsection contentsection__top light-sand-bg" data-ste-section="Benefits_71429" data-background-theme="light-sand-bg">
<div class="parsys col col--large-12 col__base">
<div class="cmp cmp-title">
<div class="headline__base">
<p>The SITRANS F M MAG 6000 I and the SITRANS F M MAG 6000 I Ex de <a href="https://en.wikipedia.org/wiki/Transmitter">transmitters</a> have an measuring accuracy of + 0.2% of the flow rate and are designed to meet the demands of the process industry. Both versions are based on a <a href="https://en.wikipedia.org/wiki/Microprocessor" target="_blank" rel="noopener">microprocessor</a> with a built-in <a href="https://en.wikipedia.org/wiki/Fourteen-segment_display" target="_blank" rel="noopener">alphanumeric display.</a></p>
</div>
</div>
</div>
</section>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-6000i-6000iex-transmitter/">MAG 6000I / 6000I(Ex) Transmitter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://instrumetrics.com/product/mag-6000i-6000iex-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MAG 8000 Battery Powered Magnetic Flowmeter</title>
		<link>https://instrumetrics.com/product/mag-8000-battery-powered-magnetic-flowmeter/</link>
					<comments>https://instrumetrics.com/product/mag-8000-battery-powered-magnetic-flowmeter/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 15 Mar 2022 12:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://instrumetrics.com?post_type=product&#038;p=508</guid>

					<description><![CDATA[<p>The SITRANS FM MAG 8000 program of battery-operated <a href="https://en.wikipedia.org/wiki/Water_metering" target="_blank" rel="noopener">water meter</a>s gives you the flexibility to install a reliable water flow meter virtually anywhere without sacrificing accuracy or performance.</p>
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="e42a1643-db59-46ec-bed5-1d04f1ec4908">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Flexible installation - <a href="https://en.wikipedia.org/wiki/IP_Code" target="_blank" rel="noopener">IP68</a> (NEMA 6P) compliance allows installation in soil or underwater</li>
<li>Low pressure loss and excellent <a href="https://instrumetrics.com/product-category/calibration-test-equipment/leak-detection/" target="_blank" rel="noopener">leak detection</a></li>
<li>Optimized lining allows good metering performance with low <a href="https://en.wikipedia.org/wiki/Fluid_dynamics" target="_blank" rel="noopener">flow</a></li>
<li>No maintenance - no moving parts and battery life of up to 15 years</li>
<li>Maximum freedom in installations with low inlet and outlet distances</li>
<li>Approved for <a href="https://en.wikipedia.org/wiki/Measuring_Instruments_Directive" target="_blank" rel="noopener">MID-001</a> without defined length of inlet and outlet</li>
<li>Remote access possible - running flow data through optional wireless 3G / <a href="https://en.wikipedia.org/wiki/UMTS" target="_blank" rel="noopener">UMTS</a> communication module<br />
allows for remote reading of comprehensive measurement data via a variety of protocols, e.g. <a href="https://en.wikipedia.org/wiki/SMS" target="_blank" rel="noopener">SMS</a>, <a href="https://en.wikipedia.org/wiki/Simple_Mail_Transfer_Protocol" target="_blank" rel="noopener">SMTP</a>(S) or <a href="https://en.wikipedia.org/wiki/File_Transfer_Protocol" target="_blank" rel="noopener">FTP</a>(S).</li>
</ul>
</div>
</div>
</div>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-8000-battery-powered-magnetic-flowmeter/">MAG 8000 Battery Powered Magnetic Flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SITRANS FM MAG 8000 program of battery-operated <a href="https://en.wikipedia.org/wiki/Water_metering" target="_blank" rel="noopener">water meter</a>s gives you the flexibility to install a reliable water flow meter virtually anywhere without sacrificing accuracy or performance.</p>
<div class="cmp cmp-title">
<div class="headline__base">
<h3 class="headline__text" data-ste-component="headline">Benefits</h3>
</div>
</div>
<div class="richtext">
<div class="richtext__base heightlimiter" data-component="heightlimiter" data-label-more="More" data-label-close="Close" data-ste-component="copy" data-component-id="e42a1643-db59-46ec-bed5-1d04f1ec4908">
<div class="richtext__contentWrapper" data-heightlimiter-content-wrapper="">
<div class="richtext__content copy editrichtext" data-heightlimiter-content="">
<ul>
<li>Flexible installation &#8211; <a href="https://en.wikipedia.org/wiki/IP_Code" target="_blank" rel="noopener">IP68</a> (NEMA 6P) compliance allows installation in soil or underwater</li>
<li>Low pressure loss and excellent <a href="https://instrumetrics.com/product-category/calibration-test-equipment/leak-detection/" target="_blank" rel="noopener">leak detection</a></li>
<li>Optimized lining allows good metering performance with low <a href="https://en.wikipedia.org/wiki/Fluid_dynamics" target="_blank" rel="noopener">flow</a></li>
<li>No maintenance &#8211; no moving parts and battery life of up to 15 years</li>
<li>Maximum freedom in installations with low inlet and outlet distances</li>
<li>Approved for <a href="https://en.wikipedia.org/wiki/Measuring_Instruments_Directive" target="_blank" rel="noopener">MID-001</a> without defined length of inlet and outlet</li>
<li>Remote access possible &#8211; running flow data through optional wireless 3G / <a href="https://en.wikipedia.org/wiki/UMTS" target="_blank" rel="noopener">UMTS</a> communication module<br />
allows for remote reading of comprehensive measurement data via a variety of protocols, e.g. <a href="https://en.wikipedia.org/wiki/SMS" target="_blank" rel="noopener">SMS</a>, <a href="https://en.wikipedia.org/wiki/Simple_Mail_Transfer_Protocol" target="_blank" rel="noopener">SMTP</a>(S) or <a href="https://en.wikipedia.org/wiki/File_Transfer_Protocol" target="_blank" rel="noopener">FTP</a>(S).</li>
</ul>
</div>
</div>
</div>
</div>
<p>The post <a href="https://instrumetrics.com/product/mag-8000-battery-powered-magnetic-flowmeter/">MAG 8000 Battery Powered Magnetic Flowmeter</a> appeared first on <a href="https://instrumetrics.com">InstruMetrics</a>.</p>